Datacenter: Tampa
Tour our Tampa Facility

Front of Facility
Front Lobby, with Network Operations Center to the right
Front Lobby from Network Operation Center's perspective
Network Operation Center
Four of our nearly one hundred security cameras
Our digital time-lapse security system
Our core router with all our network uplinks to various carriers
One of the rows from Datacenter One
Wide shot of several rows from Datacenter One
Fire-Suppression Tank
Air conditioner handlers
Wide-angel shot of Datacenter Two
Several racks from Datacenter Two
One of the multiple-redundant facility power regulators
Incoming power switch
One of the strings of batteries
Our Location
Our Tampa facility is located on Gandy Boulevard in Tampa, about 5 miles from Macdill Airforce Base. The facility is located in what used to be a very large furniture store. The building was gutted and completely remodeled with suites, several data-centers, and plenty of office space.
Our Facility
Our Tampa building is over 88,000 square feet in size. This area is segregated into three data-centers, the NOC, with the rest separated into suites and office space of varying sizes.
Our Security
This facility is protected by over 100 cameras which are connected to a digital time-lapse recording system. In addition to the cameras, the building requires digital key-card entry at every door. To gain access to the data-center itself, you must swipe a keycard at three doors.
Physical security into any Sago Networks facility is several levels. All employees, customers and contractors are restricted to the necessary levels of access determined by job function and service. All customers are required to provide a government issued ID card/driver's license to place on file before being allowed into the facility.
Any persons not identified with a company prior to coming to a Sago Networks facility will be asked to provide identification and Sago Networks will contact the person of authorization for the account before access is granted. Customer's entering the facility are required to sign in with network operations center personnel and will be let into the facility by a network operations center employee.
Our Power
The power needs of a facility such as this is tremendous. While the space available at our facilities is extensive, it is nothing without the power infrastructure to sustain it. Each of Sago Networks facilities has diverse power feeds, redundant generators, and N+2 UPS systems. The power system is further carried by PMM (Power Management Module) systems.
Our Environment
When considering co-locating equipment or leasing a dedicated server, environmental conditions are a major consideration in your choice. Sago Networks has over 200 tons of CRAC (Computer Room Air Conditioning) in it's facilities. CRAC equipment is also setup in an N+2 configuration to make sure that any CRAC equipment failure has no impact of the environmental conditions in the co-location and server farm areas. The CRAC equipment also monitors and maintains the humidity of each area, ensuring your equipment is never negatively impacted.